Radio over IP for Complex Situations
The Orion Systems Radio over IP (RIP) device interconnects multiple 4-Wire E&M radios and FXO Telephone interfaces over a LAN/WAN to Orion IP Consoles and/or an IP Voice Communication Switch (IP-VCS).
Radio over IP Device Interfaces:
- Radio Interfaces = 4 or 8
- Voice over IP (VoIP) / Radio over IP Gateway (RoIP)
- Operation = Duplex/Simplex
- Electrical = 600 Ohm Balanced Tx/Rx Pair
- 150 Ohm jumper option Tx/Rx
- Transformer Isolated
- PTT or VOX Keying
- Keying = Solid State or Tone
- AGC
Optional
- Telephone Interfaces = 4
- 2-Wire FXO

Each RIP device is equipped with either four or eight 4-Wire E&M Radio interfaces. As an option 2-Wire FXO POTS telephone interfaces can be added to the unit. Each radio interface includes a full duplex non-blocking Tx/Rx radio communication. The RIP device is capable of transmitting and receiving audio on all the radio and telephone interfaces simultaneously. When paired with Orion IP Consoles or an Orion IP-VCS the RIP device performs as an Analog to VoIP/RoIP gateway
Each radio interface consists of 600/150 Ω balanced analog transmit and receive transformer isolated audio pair. Radio keying utilizes a solid state contact closure (E&M). Radio control can be accomplished via optional RS232 interfaces, parallel interfaces, or opto coupled interfaces.
Management and configuration is accomplished using a Web browser. Settings such TX/RX line level. AGC enable/disable, and VOX level detection are set using a standard web interface. A user name password must be provided to access the unit.
Size / Power:
Size: 1.63” high x 8.5” inches wide x 12” deep
19” Rack Mounting Options:
1 device per rack unit with mounting ears
2 devices per 1 rack unit with mounting shelf
Input Voltage:
100 to 250 VAC / 50—65 Hz; external supply
12v DC nominal
Power Consumption: 30W maximum
Temperature & Humidity
Operating Temperature: 0ºC to 40ºC (32ºF to 104ºF)
Storage Temperature: -10ºC to 60C (14ºF to 140ºF)
Operating Humidity: 10%-90% Noncondensing
Storage Humidity: 5%-95% Noncondensing
Reliability
Mean Time Between Failures— 50,000 hours
Mean time to Repair (MTTR) < 0.5 hour.
Radio Interfaces
Filtered band of 300Hz to 3,300Hz, ≥ +/-2dB;
Signal to Noise (S/N) ratio >45dB;
Distortion <2%; and
Channel cross talk <50dB
Miscellaneous:
Warranty: 1 year
Weight: 5lbs
Fanless
RoHS compliant
Contact our Engineers today with your specifications
cost effective | customized for easy integration